The troubleshooting and solutions for communication charging stations can be summarized as follows:

1、 Charging station cannot start or has no response
1. Check the power supply: Ensure that the charging station power supply is connected, the air switch in the distribution box is not tripped, and use a multimeter to measure whether the input voltage is normal.

2. Check the charging station indicator light: If the red light is constantly on or flashing, it may be an internal fault and after-sales service should be contacted; If the green light is not on, check if the power or communication line is normal.

7KW AC charging station

3. Confirm the status of the emergency button: Some charging stations are equipped with an emergency stop button. After confirming whether it has been accidentally touched, reset it.

2、 Charging gun cannot be inserted or removed
1. Check the vehicle charging port: Clean any foreign objects or damaged parts to ensure that the charging gun matches the vehicle model.
2. Unlock the charging gun: For the charging gun that needs to be unlocked, unlock it through the APP/card swiping or vehicle center console operation; If the machine gets stuck, you can try gently shaking the charging gun and slowly pulling it out.

3、 Interruption during charging
1. Check for overload or overheating protection: Ensure that the cooling port of the charging station is not blocked and the ambient temperature is moderate.
2. Observe power grid fluctuations or power outages: Wait for the power grid to recover before continuing charging.
3. Check the BMS protection of the vehicle: Check the dashboard prompts to determine if charging has been terminated due to abnormal temperature or voltage.

4、 Abnormal screen display or black screen
1. Restart the charging station: Long press the power button to try restarting and check if the screen cable is loose.
2. Contact the operator: If the system failure persists, contact the operator to remotely restart or upgrade the system firmware.

5、 Leakage alarm or trip
1. Stop using immediately: Check if the gun wires and sockets are damaged or if there is water ingress, and ensure safety before use.

In addition, for the daily use of communication charging stations, regular maintenance and safety reminders should be paid attention to, such as cleaning the surface dust and debris of the charging station, avoiding use in damp and flammable environments, and not disassembling the high-voltage components inside the charging station by oneself. If encountering an unsolvable fault, the charging station model, number, description of the fault phenomenon, and other information should be provided to contact after-sales personnel for handling.
Palabras clave calientes:

What is the difference between a charging cabinet and a battery swapping cabinet?

The charging cabinet is used by users to charge their own batteries. They need to unplug their own batteries, put them in the cabinet,

2025-03-21 Más información
What is the difference between a charging cabinet and a battery swapping cabinet?

In which scenarios is the battery swapping cabinet suitable for use?

In order to solve the pain points of electric vehicle charging and endurance, efficient and convenient shared battery swapping cabinets have emerged.

2025-03-21 Más información
In which scenarios is the battery swapping cabinet suitable for use?

How is the standardization progress of current battery swapping cabinets.

At present, the standardization progress of battery swapping cabinets is steadily advancing, and a series of specific standardization plans or standards will be introduced in the future to promote the standardized development of the industry.

2025-03-20 Más información
How is the standardization progress of current battery swapping cabinets.

What are the benefits of installing electric bicycle charging cabinets and charging stations.

The number of electric bicycles is increasing, and how to safely and conveniently charge them is a problem for many people.

2025-03-20 Más información
What are the benefits of installing electric bicycle charging cabinets and charging stations.

How to solve the charging problem of shared electric bicycles on the streets?

In recent years, shared electric bicycles, as an emerging green mode of transportation, have quickly emerged as a new favorite in the urban short distance travel market due to their convenience,

2025-03-19 Más información
How to solve the charging problem of shared electric bicycles on the streets?

Analysis of the Development Trend of Battery Swap Cabinets in 2025.

As an important component of the new energy field, the future development trend of battery swapping cabinets can be analyzed from the following aspects:

2025-03-19 Más información
Analysis of the Development Trend of Battery Swap Cabinets in 2025.
china ev charging companies-SRE Power
Síguenos tiktok Linkedin Youtube facebook
Contacta con nosotros

Dirección:2-903, Building T2, Haiku Technology Building, Bao'an District, Shenzhen, Guangdong, China.

Teléfono:0755-23054220

Correo electrónico:Info@srepowerne.com

SRE Power WhatsAppWhatsApp Contact

Copyright @ China EV carga rápida fabricantes y empresas y proveedores y proveedor y proveedor-Energía SRE